Max. Current: | 2000A | Max. Voltage: | 40.5KV |
---|---|---|---|
Standard: | IEC | Rated Current: | 630A,1250A, 1600A,2000A |
Rated Voltage: | 40.5KV | Mechanical Life: | 10000 |
Port: | NINGBO | ||
High Light: | transformer disconnect switch,outdoor disconnect switch |
In electrical engineering, a disconnector, disconnect switch or isolator switch is used to ensure that an electrical circuit is completely de-energized for service or maintenance. Such switches are often found in electrical distribution and industrial applications, where machinery must have its source of driving power removed for adjustment or repair. High-voltage isolation switches are used in electrical substations to allow isolation of apparatus such as circuit breakers, transformers, and transmission lines, for maintenance. The disconnector is usually not intended for normal control of the circuit, but only for safety isolation. Disconnectors can be operated either manually or automatically.
Unlike load switches and circuit breakers, disconnectors lack a mechanism for suppression of electric arcs, which occurs when conductors carrying high currents are electrically interrupted. Thus, they are off-load devices, with very low breaking capacity, intended to be opened only after current has been interrupted by some other control device. Safety regulations of the utility must prevent any attempt to open the disconnector while it supplies a circuit. Standards in some countries for safety may require either local motor isolators or lockable overloads (which can be padlocked).
Disconnectors have provisions for a lockout-tagout so that inadvertent operation is not possible. In high-voltage or complex systems, these locks may be part of a trapped-key interlock system to ensure proper sequence of operation. In some designs, the isolator switch has the additional ability to earth the isolated circuit thereby providing additional safety. Such an arrangement would apply to circuits which inter-connect power distribution systems where both ends of the circuit need to be isolated.
A switch disconnector combines the properties of the disconnector and the load switch, so it provides the safety isolation function while being able to make and break nominal currents.
Item | Unit | Data | ||
Rated voltage | KV | 40.5/72.5/126 | ||
Rated lnsulating level |
1min power fequncy |
To earth | KV | 95/140/230 |
Fracture | KV | 115/160/245 | ||
lmpulse voltage withstand | To earth | KV | 185/325/550 | |
Fracture | KV | 215/375/630 | ||
Rated frequency | HZ | 50 | ||
Rated current | A | 630/1250/1600/2000 | ||
Rated short time current withstand | KA | 20/31.5/40/40 | ||
Rated peak current withstand | KA | 50/80/100/100 | ||
Rated short circuit cont.current:Mian/earth blade | S | 4/2 | ||
Rated teminal mechanical load | Vertical | N | 750/1000 | |
Horizontal | N | 500/750 | ||
Vertical Force | N | 750/1000 | ||
Creepage distance | MM | 1013/1256,1813/2248,3150/3906 | ||
Mechanical life | Times | 2000 | ||
Manual operating mechanism | Model | CS17,CS17G | ||
Voltage of control circuit | V | AC220 DC110 DC220 | ||
Electic operating mechanism | Voltage of motor | V | AC380 DC220 DC220 | |
Voltage of control circuit | V | AC220 DC110 DC220 |
Rated volt | A | A1 | H | E | C | D |
40.5 | 1200 | 1075 | 1070 | 1400 | 240 | 300 |
72.5 | 1600 | 1285 | 1295 | 2200 | 240 | 300 |
126 | 2000 | 1660 | 1695 | 3000 | 240 | 300 |
Q1. Can we have our logo or company name to be printed on your products or the package?
Yes,you can.Logo and company name can be printed on our products by silk screen printing.You can send us the artwork by email in JPEG or TIFF format.
Q2. What is lead time?
Usually 3-15 working days, On-Time delivery
Q3. Why us?
All products comply with the requirements of GB national standards, IC, ANSI and other international standards, and the requirements of company's technology standards.
Q4. How do you make our business long-term and good relationship?
1. Our high quality and competitive price are the most important factors to maintain long-term and good relation -ship with our customers.
2. Good service is our basic principle for every customers.
Q5. Can I have a visit to your factory before the order?
Sure,welcome to visit our factory.