11kv Load Break Isolator 3 Phase Indoor Hv 630A 1250A Rated Currency

Basic Information
Place of Origin: china
Brand Name: XK
Certification: ISO9001 / GB / IEC
Model Number: FN12
Minimum Order Quantity: 1 Piece/Pieces
Price: Negotiation
Packaging Details: EXPORTING PACKING
Supply Ability: 100 Piece/Pieces per Month
Standard: IEC Rated Current: 630A,1250A
Rated Voltage: 11KV Mechanical Life: 10000
Keywords: Indoor H.v. Load Breaking Switch Port: NINGBO
High Light:

load break isolator

,

high voltage isolator switch

11kv load break 3 phase load break isolating switch indoor h.v. load breaking switch

Hot sale 11KV safety indoor AC high voltage load breaker switch

Product Description

 
Load brake switch (LBS) - this is a switching device in the power distribution network, which is capable to switch off the power lines under nominal load. It is used to divide the power line into smaller sections, hence its second designation as a sectionalizer. If reclosers and LBSs are remotely operated, then during the short circuit, a manipulation (LBS switching off and on) is done in cooperation with a recloser in non-voltage pauses (when recloser is off) to protect the LBS from higher currents than nominal. When the LBS is manipulated in standard conditions with nominal load, they occur the arc discharges. Therefore, load break switches are mostly equipped with various types of arc discharges extinguishers (spring, oil, vacuum, etc.).
Indicator - it is a device indicating the states of voltage and current at a given location. The power line is not manipulated and therefore it is a cheaper device designed to mark an affected area as accurately as possible, so a repair can be done in the shortest time.

 

  11kv Load Break Isolator 3 Phase Indoor Hv 630A 1250A Rated Currency 0

ltem Unit Data
Rated voltage KV FN12-12D/630 FN12-12(R)D/125
Rated frequency HZ 12
Rated current A 50
1min power frequency withstand voltage KV 42 to ground and phases fracture 48
Lightning impulse withstand voltage KV 75 to ground and phases fracture 85
Rated thermal stable current KA
630
100
Rated dynamic stable current KA
50
Rated switching current(peak) KA
50
50
Rated short-circuit current(expected) KV  
31.5
Maximum breaking current threshold HZ Fuse characteratic curve accorting
Minimum breaking current A Fuse characteratic curve accorting
Rated transfer current KV
50
1.5
Maximum breaking current KV 1.8
Breaking OFF-load transformer capacity KV/A 1250
Rated cable charging current A 10
Rated active load current breaking times Times 10000
Opening time when striker strikes S <0.06
Earth switch thermal current switch KA 20(2S)
Thermal stable current of earth switch KA 50 50
Motor operating power supply voltage V AC/DC 110/220

11kv load break 3 phase load break isolating switch indoor h.v. load breaking switch

 
ltem Unit Data
FN12-10D/630 FN12-10(R)D/125
The total traveling distance of moving contact mm 200+8-2
Phase center distance (Before energy storage) mm 210±15
Moving contact overtravel distance mm 40±2
Auxiliary contact opening distance mm >150
Opening/Closing time difference among three phase ms <3
Opening speed m/s >2.8 >2.8
Closing speed m/s >3.8
Distance between metal flexible door and torch mm >125
Fracture distance of earth switch mm >150
Main circuit resistance Ω <120 <300
Maximum operating torque NM >160

11kv load break 3 phase load break isolating switch indoor h.v. load breaking switch

11kv Load Break Isolator 3 Phase Indoor Hv 630A 1250A Rated Currency 1  

 11kv Load Break Isolator 3 Phase Indoor Hv 630A 1250A Rated Currency 2 
FAQ

11kv Load Break Isolator 3 Phase Indoor Hv 630A 1250A Rated Currency 3

Q1. Can we have our logo or company name to be printed on your products or the package?
Yes,you can.Logo and company name can be printed on our products by silk screen printing.You can send us the artwork by email in JPEG or TIFF format.
Q2. What is lead time?
Usually 3-15 working days, On-Time delivery
Q3. Why us?
All products comply with the requirements of GB national standards, IC, ANSI and other international standards, and the requirements of company's technology standards.
Q4. How do you make our business long-term and good relationship?
1. Our high quality and competitive price are the most important factors to maintain long-term and good relation -ship with our customers.
2. Good service is our basic principle for every customers.
Q5. Can I have a visit to your factory before the order?
Sure,welcome to visit our factory.

Contact Details
Liu

Phone Number : +8613587461262