Indoor Lbs Load Break Switch 11kv 20 Kv / Hv High Voltage Isolators Easy Operation

Basic Information
Place of Origin: china
Brand Name: XK
Certification: ISO9001 / GB / IEC
Model Number: FN12
Minimum Order Quantity: 1 Piece/Pieces
Price: Negotiation
Packaging Details: EXPORTING PACKING
Supply Ability: 100 Piece/Pieces per Month
Keywords: 11kv Indoor Load Break Switch Max. Current: 1250A
Max. Voltage: 12KV Standard: IEC
Rated Current: 630A,1250A Rated Voltage: 12KV
Mechanical Life: 10000 Port: NINGBO
High Light:

load break isolator

,

high voltage isolator switch

Hot sale 12KV safety indoor AC high voltage load breaker switch

Product Description

  Indoor Lbs Load Break Switch 11kv 20 Kv / Hv High Voltage Isolators Easy Operation 0

ltem Unit Data
Rated voltage KV FN12-12D/630 FN12-12(R)D/125
Rated frequency HZ 12
Rated current A 50
1min power frequency withstand voltage KV 42 to ground and phases fracture 48
Lightning impulse withstand voltage KV 75 to ground and phases fracture 85
Rated thermal stable current KA
630
100
Rated dynamic stable current KA
50
Rated switching current(peak) KA
50
50
Rated short-circuit current(expected) KV  
31.5
Maximum breaking current threshold HZ Fuse characteratic curve accorting
Minimum breaking current A Fuse characteratic curve accorting
Rated transfer current KV
50
1.5
Maximum breaking current KV 1.8
Breaking OFF-load transformer capacity KV/A 1250
Rated cable charging current A 10
Rated active load current breaking times Times 10000
Opening time when striker strikes S <0.06
Earth switch thermal current switch KA 20(2S)
Thermal stable current of earth switch KA 50 50
Motor operating power supply voltage V AC/DC 110/220

11kv indoor load break switch 24kv load break switch high voltage isolators

 
ltem Unit Data
FN12-10D/630 FN12-10(R)D/125
The total traveling distance of moving contact mm 200+8-2
Phase center distance (Before energy storage) mm 210±15
Moving contact overtravel distance mm 40±2
Auxiliary contact opening distance mm >150
Opening/Closing time difference among three phase ms <3
Opening speed m/s >2.8 >2.8
Closing speed m/s >3.8
Distance between metal flexible door and torch mm >125
Fracture distance of earth switch mm >150
Main circuit resistance Ω <120 <300
Maximum operating torque NM >160

11kv indoor load break switch 24kv load break switch high voltage isolators

Indoor Lbs Load Break Switch 11kv 20 Kv / Hv High Voltage Isolators Easy Operation 1  

  

We are recognized as a successful name of Load Break Switch in the market at present. Being compact in size these are used in smallest of the devices. These also traverse up / down or tilt outside or on one side of the sensor stem. These are made available to the customers at industry leading rates. These are provided as per the set industry norms and guidelines.

Features
Side mounting
Efficient sensor stems
Breaks off the loads

Applications
Power supplies
Electrical industry
Electricity components
Request
Callback

Contact Details
Liu

Phone Number : +8613587461262