36kv 11kv Transformer Load Break Switch / Fuse Switch Disconnector Indoor

Basic Information
Place of Origin: china
Brand Name: XK
Certification: ISO9001 / GB / IEC
Model Number: FN12
Minimum Order Quantity: 1 Piece/Pieces
Price: Negotiation
Packaging Details: EXPORTING PACKING
Supply Ability: 100 Piece/Pieces per Month
Max. Current: 1250A Max. Voltage: 12KV
Standard: IEC Rated Current: 630A,1250A
Rated Voltage: 12KV Mechanical Life: 10000
Keywords: 36kv Load Break Port: NINGBO
High Light:

load disconnect switch

,

high voltage isolator switch

Hot sale 12KV safety indoor AC high voltage load breaker switch

Product Description

36kv 11kv Transformer Load Break Switch / Fuse Switch Disconnector Indoor 0

 

Key benefits

Efficient solution for transformers protection
Easy application in wide range of configurations
Smart grid and network automation ready
Capability for protection of up to 3000kVA 36 kV transformers
Full range protection in combination with CEF-S fast acting current limiting fuses
Safe and reliable solution for short circuit currents interruptions

ltem Unit Data
Rated voltage KV FN12-12D/630 FN12-12(R)D/125
Rated frequency HZ 12
Rated current A 50
1min power frequency withstand voltage KV 42 to ground and phases fracture 48
Lightning impulse withstand voltage KV 75 to ground and phases fracture 85
Rated thermal stable current KA
630
100
Rated dynamic stable current KA
50
Rated switching current(peak) KA
50
50
Rated short-circuit current(expected) KV  
31.5
Maximum breaking current threshold HZ Fuse characteratic curve accorting
Minimum breaking current A Fuse characteratic curve accorting
Rated transfer current KV
50
1.5
Maximum breaking current KV 1.8
Breaking OFF-load transformer capacity KV/A 1250
Rated cable charging current A 10
Rated active load current breaking times Times 10000
Opening time when striker strikes S <0.06
Earth switch thermal current switch KA 20(2S)
Thermal stable current of earth switch KA 50 50
Motor operating power supply voltage V AC/DC 110/220

11kv switch disconnector 36kv load break indoor load break switch 11kv

 
ltem Unit Data
FN12-10D/630 FN12-10(R)D/125
The total traveling distance of moving contact mm 200+8-2
Phase center distance (Before energy storage) mm 210±15
Moving contact overtravel distance mm 40±2
Auxiliary contact opening distance mm >150
Opening/Closing time difference among three phase ms <3
Opening speed m/s >2.8 >2.8
Closing speed m/s >3.8
Distance between metal flexible door and torch mm >125
Fracture distance of earth switch mm >150
Main circuit resistance Ω <120 <300
Maximum operating torque NM >160

11kv switch disconnector 36kv load break indoor load break switch 11kv36kv 11kv Transformer Load Break Switch / Fuse Switch Disconnector Indoor 1

 

36kv 11kv Transformer Load Break Switch / Fuse Switch Disconnector Indoor 236kv 11kv Transformer Load Break Switch / Fuse Switch Disconnector Indoor 3 

Contact Details
Liu

Phone Number : +8613587461262